描述:Lumafluor代理,Lumafluor上海代理,Lumafluor北京代理, Lumafluor總代理, Lumafluor一級(jí)代理, Lumafluor 特約代理上海起發(fā)實(shí)驗(yàn)試劑有限公司 Lumafluor專業(yè)代理,具體產(chǎn)品信息歡迎電詢:4006551678
世界*實(shí)驗(yàn)材料供應(yīng)商 Lumafluor 正式授權(quán)上海起發(fā)為其中國(guó)代理, Lumafluor 在一直是行業(yè)的*,一直為廣大科研客戶提供zui為優(yōu)質(zhì)的產(chǎn)品和服務(wù),上海起發(fā)一直秉承為中國(guó)科研客戶帶來的產(chǎn)品,的服務(wù),簽約 Lumafluor 就是為了給廣大科研客戶帶來更加完善的產(chǎn)品和服務(wù),您的滿意將是我們zui大的收獲
Lumafluor 中國(guó)代理, Lumafluor 上海代理, Lumafluor 北京代理,Lumafluor 廣東代理, Lumafluor 江蘇代理Lumafluor 湖北代理,Lumafluor 天津,Lumafluor 黑龍江代理,Lumafluor 內(nèi)蒙古代理,Lumafluor 吉林代理,Lumafluor 福建代理, Lumafluor 江蘇代理, Lumafluor 浙江代理, Lumafluor 四川代理,
美國(guó)熒光示蹤試劑供應(yīng)商,供應(yīng)Red Retrobeads,Green Retrobeads,
公司:www.Lumafluor.com
訂購(gòu)信息
Item | Price | |
Red Retrobeads™ (100 µl) | $155.00 | |
Red Retrobeads™ IX (100 µl) | $165.00 | |
Green Retrobeads™ IX (100 µl) | $165.00 |
|
Item | Price | |
Red Retrobeads™ (100 µl) | 2635 | lumafluor |
Red Retrobeads™ IX (100 µl) | 2805 | lumafluor |
Green Retrobeads™ IX (100 µl) | 2805 | lumafluor |
Item | Price | |
Red Retrobeads™ (100 µl) | $155.00 | |
Red Retrobeads™ IX (100 µl) | $165.00 | |
Green Retrobeads™ IX (100 µl) | $165.00 |
|
Protocols for Use of Fluorescent Latex Microspheres (rev. 11/07)
This sheet summarizes most of the procedures for using fluorescent latex microspheres, or "beads" as a retrograde neuronal tracer. Special information about green beads is at the end of this protocol. Further details are presented in: Katz, L.C., Burkhalter, A., and Dreyer, W.D. Fluorescent latex microspheres as a retrograde neuronal marker for in vivo and in vitro studies of visual cortex. Nature 310: 498-500 (1984), and Katz, L.C. and Iarovici, D.M. Green fluorescent latex microspheres: a new retrograde tracer. Neuroscience 34: 511-520 (1990). Questions, problems, or comments concerning the use of this material can be directed to: info@lumafluor.com or phone 919 801-6244.
How supplied: The enclosed vial(s) contains a concentrated solution of beads suspended in distilled water. If red beads are being used for retrograde tracing of neuronal pathways, the solution can be used as is, or diluted. In rat visual cortex, dilutions of 1:4 do not appear to reduce the quality or extent of retrograde labeling when using red beads. However, for initial experiments we strongly recommend using the solution full strength. In addition to distilled water, standard salt solutions (NaCl, KCl) can be used as diluents. The green beads, as supplied, are compley prepared for retrograde tracing experiments. Dilution of green beads is not recommended.
Storage: The bead solution should be stored in a humidified container, in a refrigerator, to prevent evaporation.Do not freeze! Beads that have been frozen will not work, and cannot be rescued. If the beads dry out, they cannot be reconstituted. No shelf life has been established for this material, but, when properly stored, it remains good for several years.
Application: Beads are best injected using pressure (e.g. a 1 ml Hamilton syringe, or pressurized air injection system). For local circuit work, very small volumes (30-50 nl) have been injected through glass pipettes with 30-50 mm diameter tips. For routine retrograde tracing, larger volumes (0.1-0.3 ml) and larger diameter pipette tips are used. However, even with large injections beads do not diffuse far from the injection site (usually less than 1 mm). Thus in order to label all or most of the neurons projecting to a large structure, several injections should be made. Iontophoretic application of beads is not recommended as an effective means to deliver the tracer. However, the beads do have a net negative charge.
Survival times: The minimum effective post-injection survival time in most warm-blooded vertebrate systems is approximay 24 hours. Labeling intensity increases with longer survival, up to 48 hours. After 48 hours, no increase (or decrease) in labeling intensity is observed. These values may be considerably different in cold-blooded animals, and initial survival times of a week are recommended. The maximum survival time has not been established, but labeling is unchanged in either quality or extent even after 14 month survival times. Cells probably are permanently marked. No toxic effects on either animals or neurons have been observed.
Fixation and processing: Standard fixation is a 0.1 M phosphate buffer wash followed by 4% paraformaldehyde in 0.1 M phosphate buffer (pH 7.4). Glutaraldehyde will produce substantial tissue autofluorescence which may obscure bead-labeled neurons, and should be avoided if possible. Green beads will be compley invisible in glutaraldehyde fixed material. Frozen sections are collected in phosphate buffer, mounted on gelatin-coated slides, and air-dried. After complete drying, slides can be cleared in xylene for 1 minute, and covers lipped with Fluoromount or Krystalon. Fluoromount is available from Atomergic Chemetals Corp., Farmingdale, NY; Krystalon from Harleco (EM Industries), Gibbstown, NJ. Brief exposures to alcohols and xylenes are not harmful, but long exposures (over 5 minutes) will destroy the beads. Beads are very sensitive to glycerol, and will fade rapidly if mounted in glycerol-containing solutions. Methyl salicylate is preferable to glycerol in situations where non-permanent clearing/mounting agents are indicated. If slides are kept in the dark, the labelling in cells will not fade for at least one year (although background autofluorescence may increase substantially). Thus far, attempts to retain bead labeling after plastic embedding have not been successful.
Observation: The dye in the red beads is rhodamine, thus any fluorescence filter set for rhodamine can be used. Some older Nikon rhodamine filter sets give a very high background, which can make labeled cells invisible. Good results have been obtained with both Zeiss and Leitz standard rhodamine filters. For green beads, a wide-band fluorescein filter works well. Filter sets for Lucifer yellow give a more intense signal, but at the expense of higher background. Narrow-band fluorescein filters will give a much weaker signal than a broad-band filter. Beads do not fade appreciably even after long periods of observation or photomicrography.
Labeling is usually not visible with low power, low numerical aperture dry objectives (e.g. X4, X10). If cells are strongly labeled, a X10 immersion objective (numerical aperture of 0.4 or greater), or higher power dry objectives, will usually reveal the cells. However, frequently a X25 immersion objective will reveal very clearly labeled cells that lower power objectives miss. These caveats are especially true for green beads. Before deciding that an experiment did not work, examine sections in the vicinity of the injection site with immersion objectives. Numerous locally labeled cells should be present.
Additional information for green bead users: In work that has been done so far, it appears that younger animals transport the label better than older animals. In addition, tissue autofluorescence is lower in the younger animals. Therefore, it is advisable to use younger animals, if possible, in experiments involving green beads.
Because the green beads are excited at shorter wavelengths than red beads, tissue autofluorescence is a greater problem. Therefore, efforts to minimize autofluorescence will produce a better contrast signal. Ways to reduce autofluorescence include: 1) using thinner sections (e.g. 30 um rather than 40 or 50) 2) using younger animals, and 3) examining sections promptly after coverslipping (background increases over time).
我們公司zui大優(yōu)勢(shì)是強(qiáng)大的采購(gòu),
1:基本什么都能進(jìn)口,血清,抗體,耗材,還有部分限制進(jìn)口的,
2:貨品全,現(xiàn)經(jīng)營(yíng)過700多個(gè)品牌,基本所有生物試劑耗材都可以進(jìn)口,特別是冷偏的產(chǎn)品那就更有優(yōu)勢(shì),
3:提供加急服務(wù),一般1-2周到貨,超過時(shí)限加急費(fèi)全免
4:價(jià)格公道,絕大部分價(jià)格有優(yōu)勢(shì),當(dāng)然不能保證100%產(chǎn)品都是,因?yàn)橐馕吨鴽]有服務(wù).
5:良好的信譽(yù),大部分客戶我們提供貨到付款服務(wù),客戶包括清華,北大 交大 復(fù)旦,中山等100多所大學(xué),ROCHE,阿斯利康,國(guó)藥 ,fisher等500多家公司
6:我們還是Santa,Advanced Biotechnologies Inc, Lumafluor,bangs,BBInternational,crystalchem,dianova,FD Neurotechnologies,Inc. FormuMax Scientific,Inc, GePromegaridege, Glycotope Biotechnology GmbH; iduron,Innovative Research of America, Ludger, neuroprobe,Lumafluor, Polysciences,prospecbi, QA-BIO,quickzyme,FULLERLABS,INC,sterlitech;sysy,TriLink BioTechnologies,Inc;worthington-biochem,zyagen等幾十家國(guó)外公司授權(quán)代理。
7:我們還是invitrogen,qiagen,Lumafluoram,sigma;Promega,roche,merck, rnd,BD, GE,pierce,BioLegend等*批發(fā),歡迎合作。
上海起發(fā)實(shí)驗(yàn)試劑有限公司
:楊建輝
400:
辦公:
*8006
企業(yè):
:http://www.qfbio.com/
地址:上海市浦東新區(qū)晨陽路225弄東方現(xiàn)代商業(yè)廣場(chǎng)46號(hào)303室(近東亭路)